HLG-120H-24 Vivotek 120W Single Output Switching Power Supply 24VDC
- Brand: Vivotek
- Model: HLG-120H-24
- SKU: HLG-120H-24
- MPN: HLG-120H-24
$129.60
Specifications
Output
- DC Voltage - 24V
- Constant Current Region - 12 ~ 24V
- Rated Current - 5A
- Rated Power - 120W
- Ripple & Noise (Max.) - 150mVp-p
- Voltage Adj. Range - 22 ~ 27V
- Current Adj. Range
- Can be adjusted by internal potentiometer A type only
- 2.5 ~ 5A
- Voltage Tolerance - 1.0%
- Line Regulation - 0.5%
- Load Regulation - 0.5%
- Setup,Rise Time - 1200ms,50ms/115VAC 500ms,50ms/230VAC at full load ; B type 1200ms,200ms/115VAC 500ms,200ms/230VAC at 95% load
- Hold Up Time (Typ.) - 12ms at full load 230VAC / 115VAC
Input
- Voltage Range - 90 ~ 305VAC, 127 ~ 431VDC
- Frequency Range - 47 ~ 63Hz
- Power Factor (Typ.) - PF>0.98/115VAC, PF>0.95/230VAC, PF>0.93/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
- Total Harmonic Distortion - THD< 20% when output loading50% at 115VAC/230VAC input and output loading75% at 277VAC input
- Efficiency (Typ.) - 93%
- Ac Current (Typ.) - 1.4A / 115VAC, 0.6A / 230VAC, 0.55A / 277VAC
- Inrush Current (Typ.) - COLD START 60A(twidth=375μs measured at 50% Ipeak) at 230VAC
- Max. No. Of Psus On 16A Circuit Breaker - 5 units (circuit breaker of type B) / 9 units (circuit breaker of type C) at 230VAC
- Leakage Current - <0.75mA / 277VAC
Protection
- Over Current
- 95 ~ 108%
- Protection type : Constant current limiting, recovers automatically after fault condition is removed
- Short Circuit - Constant current limiting, recovers automatically after fault condition is removed
- Over Voltage
- 28 ~ 34V
- Protection type : Shut down o/p voltage with auto-recovery or re-power on to recovery
- Over Temperature - Shut down o/p voltage, recovers automatically after temperature goes down
Environment
- Working Temp. - -40 ~ +70™C(Refer to "Derating Curve")
- Working Humidity - 20 ~ 95% RH non-condensing
- Storage Temp., Humidity - -40 ~ +80™C, 10 ~ 95% RH
- Temp. Coefficient - ™0.03%/™C(0 ~ 50™C)
- Vibration - 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
Safety & EMC
- Safety Standards - UL8750, CSA C22.2 No. 250.0-08, ENEC, TUV EN61347-1, EN61347-2-13 independent IP65 or IP67, J61347-1, J61347-2-13 approved ; design refer to UL60950-1, TUV EN60950-1
- Withstand Voltage - I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
- Isolation Resistance - I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25™C/ 70% RH
- EMC Emission - Compliance to EN55015, EN55022 (CISPR22) Class B, EN61000-3-2 Class C (50% load) ; EN61000-3-3
- EMC Immunity - Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level (surge 4KV), criteria A
Others
- MTBF - 192.2K hrs min. MIL-HDBK-217F (25™C)
- Dimension - 220*68*38.8mm (L*W*H)
- Packing - 1.12Kg; 12pcs/14.4Kg/0.8CUFT